Radio Frequency Surgical Unit

What is the 4MHz Radio Frequency Surgical Unit? Dr.Oppel's electrode is not being heated by itself. Electrode lets the cellular tissue produce the joule heat, and operates hemostasis, cutting, and coagulation. 4MHz radio frequency makes possible precise cutting and deep coagulation even in blood. There is no carbonization and damages to the surrounding cellular tissue by electric spark, and the safety secured. Specially developed various Bipolar and Monopolar electrodes for OB/GYN,PS/DER, Urology has outstanding performance in Micro Surgery by their excellent output time function.

Download Catalog Inquire Now
MODEL NAMEDr.Oppel ST-501
OUTPUT POWERMONOPOLAR: 125W (Average power on 200 load) 700W (Peak power on 200 load) / BIPOLAR : 50W (Average power on 200 2 load) 350W (Peak power on 200 load)
FREQUENCY4MHz (FDA, CE)
INPUT VOLTAGE (Customer-Made)100/110/120/220/230/240 VAC, 50/60Hz
TIME SELECTIONContinous,1sec, 1/2sec, 1/4sec, 1/8sec
POWER CONSUMPTION450 VA + 10% under on maximum load
WEIGHT10 kg
DIMENSIONMain Unit: 225(W) X 300(L) X 155(H)mm
OB/GYN
  • Conization or LLETZ
  • Cervical erosion
  • Condyloma
  • Bartholinitis
  • Polyp removal
  • Cysts, tumors removal
  • Laparoscopic surgery
  • Hysteroscopic surgery
  • Precise operation with an operating microscope (Tubal reversal and vasovasotomy)
  • Treatment of umbilical cord
  • Bleeding control in C/S
  • Vaginoplasty
Operating room/General Surgery/Proctology
  • Intemal hemorrhoids, external hemorrhoids
  • Anal fissure, fistula, anal prolapse
  • Periportal abscess
  • Nevus and freckle removal
  • Wart and corn removal
  • Condyloma, polyps removal
  • Circumcision
  • Osmidrosis axilla
  • Hair root removal
  • Various open surgery - Pure cutting, hemostatic cutting, coagulation, hemostasis
  • Various endoscopic surgery - Pure cutting, hemostatic cutting, coagulation, hemostasis
ENT
  • Snoring
  • Chronic hypertrophic rhinitis
  • Tonsillectomy
  • Chronic tonsillitis
  • Adenoidectomy
  • Exudative otitis media
  • Chorditis vocalis
  • Hemostatic cutting, pure cutting, coagulation
  • Hemostasis
  • Epistaxis
Ophthalmology (Ocular Plasty Surgery)
  • Blepharoplasty
  • Blepharism
  • Dacryocystorhinostomy
  • Medial (Inner) canthus correction
  • Blepharectomy
  • Blepharophimosis
Dermatology/Plastic Surgery/Urology
  • Nevus and freckle removal
  • Wart and corn removal
  • Condyloma, polyp removal
  • Osmidrosis axilla and hair root removal
  • Volume reduction of masseter muscle
  • Volume reduction of triceps brachii muscle
  • Telangiectasia
  • Varix coagulation
  • Hemostasis
  • Micro coagulation
  • Volume reduction of gastrocnemius muscle
  • Skin incisions
  • Cosmetic repair
  • Endo surgery
  • Prostatomegaly coagulation
  • Lifting of facial wrinkles
NS/OS/Pain Clinic
  • Discoplasty using spinal needle (17 gauge)
  • Radio frequency diathermy after discectomy with C-arm X-ray
  • Endoscopic radio frequency diathermy after discectomy
  • Revision surgery
  • Endoscopic surgery (Incision, coagulation, hemostasis)
  • Open surgery
    • - Incision, hemostatic cutting, coagulation (Bipolar, monopolar),micro coagulation, micro cutting
  • Various operations of NS
    • - Obstructive hydrocephalus, resection of small tumors, membranectomy, colloid cyst open, ventricle open
  • Various operation of OS
    • - Incision of meniscus, splitting lateral retinaculum, incision of synovial folds
  • Not being heated by itself, electrode lets the cellular tissue produce the Joule heat and operates Hemostasis, Cutting, and Coagulation.
  • The radio frequency output of 4MHz
    • - The precise operation is capable
    • - By minimizing damage to the cellular tissue, the fast healing can be secured.
  • Compact design with a great output power
    • - 700W peak power on 200 load
  • No odor and no smoke in operation.
  • Coagulation depth is determined by electrode,
    • - 6mm semi-ball electrode: coagulation to the 5mm in depth
    • - 4mm semi-ballelectrode: coagulation to the 3mm in depth
    • - 3mm ballelectrode: coagulation to the 2mm in depth
  • All functions can be carried out just by choosing the electrode and controlling the output power without any mode change such as pure cut, blended cut, coag, micro coag, etc.
  • The excellent functions of Hemostasis and coagulation are performed even in the massive bleeding.
  • Thanks to its low-voltage of radio frequency output, bringing up no electric spark, there is neither carbonization and nor damage to the surrounding cellular tissue,
  • Safety can be secured because this system is free from electric shock and burn which current electric surgical units make
  • Durability and long life cycle,
  • The great coagulation and cutting capabilities not only in the open surgery but also in the endoscopic surgery.
  • Bipolar and monopolar function
  • Various electrodes (Unlimited applications)